All testing of equipment shall be performed in a configuration as close as possible to the installed case. Wiring shall be consistent with the manufacturer's recommended procedures, and the equipment shall be in its housing with all covers and access panels in place, unless otherwise stated.
If the equipment is designed to be mounted in a panel, rack or cabinet, it shall be tested in this configuration.
A metallic ground plane is not required. When a means is required to support the test sample, it shall be constructed of a non-metallic, non-conducting material. However, grounding of housing or case of the equipment shall be consistent with the manufacturer's installation recommendations.
When an EUT consists of floor-standing and table-top components, the correct relative positions shall be maintained.
Typical EUT set-ups are shown in figures 5 and 6.